home *** CD-ROM | disk | FTP | other *** search
/ Personal Computer World 2009 February / PCWFEB09.iso / Software / Linux / Kubuntu 8.10 / kubuntu-8.10-desktop-i386.iso / casper / filesystem.squashfs / etc / sane.d / mustek_pp.conf < prev    next >
Text File  |  2008-05-07  |  4KB  |  104 lines

  1. # For documentation see sane-mustek_pp(5)
  2.  
  3. # Global options:
  4. # ===============
  5. #
  6. # option no_epp
  7. #
  8. #        Disable parallel port mode EPP: works around a known bug in
  9. #        the Linux parport code. Enable this option, if the backend
  10. #        hangs when trying to access the parallel port in EPP mode:
  11. #
  12. #              # SANE_DEBUG_SANEI_PA4S2=128 scanimage -L
  13. #              ...
  14. #  hangs here  -> [sanei_pa4s2] sanei_pa4s2_readbyte: read in EPP mode
  15. #     
  16. # Scanner definition template:
  17. # ============================
  18. #
  19. #  scanner <name> <port> <type>
  20. #     option <optname> <optval>?
  21. #     option <optname> <optval>?
  22. #     ...
  23. #
  24. #  where:
  25. #
  26. #     <name> is an arbitrary name for the scanner (eg. Mustek-1200CP)
  27. #
  28. #     <port> is the parallel port to which the scanner is connected
  29. #            Possible values are 0x378, 0x278, and 0x3bc. For Linux, the
  30. #            mapping between ports an numbers is different for kernel
  31. #            version 2.2 and 2.4. Port 0x378 corresponds to lp0 on 2.4 kernel.
  32. #            If you are using libieee1284, you can as well use parport0, etc..
  33. #         If you use the magic value * the port is probed.
  34. #
  35. #     <type> is an identification of the scanner type.
  36. #            Possible values are:
  37. #              - cis600    (for Mustek 600CP & OEM versions),
  38. #              - cis1200   (for Mustek 1200CP & OEM versions),
  39. #              - cis1200+  (for Mustek 1200CP+ & OEM versions),
  40. #              - ccd300    (for Mustek 600 III EPP & OEM versions)
  41. #           - ... more types will be added in the future
  42. #     
  43. #     <optname> is a name of an option, and <optval> an optional value
  44. #               for the option.
  45. #               Currently available options for *CIS* type scanners are:
  46. #                 - top_adjust <value>: 
  47. #                      Vertical adjustment of origin, in millimeter.
  48. #                      Values between -5.0 and +5.0 mm are possible 
  49. #                      (floating point).
  50. #                      Default: 0.0
  51. #                 - slow_skip: 
  52. #                      Boolean option. Disables fast skipping to the start
  53. #                      of the scan region. May be necessary in case fast
  54. #                      skipping results in inaccuracies.
  55. #                      Default: fast skipping enabled             
  56. #                 - bw <value>:
  57. #                      Black/white discrimination value for lineart scans.
  58. #                      Pixel values below that value are considered black,
  59. #                      others are considered white. Range: 0-255.
  60. #                      Default: 127
  61. #
  62. #        Currently available options for *CCD* type scanners are:
  63. #          - wait_bank <value>
  64. #               usecs to wait for a bank change. Positive integer
  65. #               values are possible. You shouldn't mess with this
  66. #               parameter.
  67. #               Default: 700
  68. #          - bw <value>
  69. #                      Black/white discrimination value for lineart scans.
  70. #                      Pixel values below that value are considered black,
  71. #                      others are considered white. Range: 0-255.
  72. #                      Default: 127
  73. #          - top <value>
  74. #               Scanlines to skip to the top area. Positive integer
  75. #               values are possible. 47 and 56 are values I know of.
  76. #               Default: 47
  77. #
  78. #
  79. # Example for a LifeTec LT9350 (Mustek 1200CP clone):
  80. #
  81. #    scanner LT9350 0x378 cis1200
  82. #       option top_adjust 0
  83. #       option bw 127
  84. #
  85. # Example for Mustek 6000P
  86. #
  87. #    scanner 6000P 0x378 ccd300
  88. #        option top 56
  89. #
  90. #
  91. # Uncomment/customize to your needs
  92. #
  93. # scanner Mustek-600CP 0x378 cis600
  94. # scanner Mustek-1200CP 0x378 cis1200
  95. # scanner Mustek-1200CP+ 0x378 cis1200+
  96. # scanner Mustek-600-IIIEP 0x378 ccd300
  97. #
  98. # auto probing:
  99. #
  100. # scanner mustek-cis600 * cis600
  101. # scanner mustek-cis1200 * cis1200
  102. # scanner mustek-cis1200+ * cis1200+
  103. # scanner mustek-ccd300 * ccd300
  104.